XG 15-25kW INVT Three-Phase On-Grid Solar Inverter XG 15-25kW
1. Efficient
* Support over capacity ratio: 1.6X DC input overload
* High energy continuous output: 1.1X AC output overload
* The MPPT efficiency is up to 99.90%
* The lowest starting voltage can reach to 160V
2. Flexible
* Intelligent IV scanning function: it can accurately locate the fault string and make the operation and maintenance more efficient
* 2 MPPT: more flexible string configuration and more choices for installation
* Remote maintenance: support online remote upgrade
* Fan drawer design: 1 minute quick fan replacement
3. Reliable
* IP66
* RCD protection, Surge protection, Input over voltage protection, AC short circuit protection, AC output over current protection, Isolation protection, PV string protection, DC ARC fault protection, Anti-islanding protection, Over temperature protection, Grouding fault monitoring, Grid monitoring, Single/multiple inverter anti-reverse protection, etc.
4. Intelligent
* Intelligent monitoring: one-stop intelligent operation and maintenance platform for users, providing comprehensive and intuitive power station data monitoring
* Support RS485 / USB / WiFi / GPRS
INVT Inverters
Product Feature
Product Introduction
Input (DC) | XG15KTR | XG17KTR | XG20KTR | XG22KTR | XG25KTR | |
Max. Input Power |
24kW | 27.2kW |
32kW |
35.2kW | 40kW | |
Max. Input Voltage | 1100V | |||||
Start Voltage | 250V | |||||
Rated Input Voltage | 600V | |||||
Full-load MPP Voltage Range | 480V ~ 800V | 520V ~ 800V | 560V ~ 800V | |||
MPPT Voltage Range | 200V ~ 1000V | |||||
Number of MPP Trackers | 2 | |||||
Number of string per MPPT | 2 / 2 2 / 3 | 2月3日 | ||||
Max. Current per MPPT | 26A | 26A / 39A | ||||
Max. Short Circuit Current per MPPT | 32A | 32A / 48A | ||||
Output (AC) | ||||||
Max. Output Current |
24.1A |
27.2A |
32.1A |
35.3A |
39.8A |
|
Rated Output Power | 15kW | 17kW | 20kW | 22kW | 25kW | |
Max. Output Power | 16.6kVA | 18.8kVA | 22.2kVA | 24.4kVA | 27.7kVA | |
Rated Grid Frequency | 50Hz / 60Hz | |||||
Rated Grid Voltage | 230Vac / 400Vac, 3L / N / PE | |||||
Power Factor | >0.99 (0.8 leading~0.8 lagging) | |||||
THDi |
<3% (Rated Power) | |||||
Efficiency | ||||||
Max. Efficiency |
98.40% |
|||||
European Efficiency | 98.00% | |||||
MPPT Efficiency | 99.90% | |||||
Protection | ||||||
DC reverse polarity protection |
Yes | |||||
Anti-islanding protection | Yes | |||||
AC short circuit protection | Yes | |||||
Residual current monitoring unit | Yes | |||||
Insulation resistance monitoring | Yes | |||||
Ground fault monitoring | Yes | |||||
Grid monitoring | Yes | |||||
PV string monitoring | Yes | |||||
Surge protection | Type II | |||||
AFCI protection | Optional | |||||
Communication |
||||||
Display |
LED / LCD / WIFI+APP | |||||
Communication |
Standard:RS485/ USB Optional:WiFi / GPRS / Ethernet |
|||||
Standard Compliance | ||||||
Grid Connection Standards |
IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4105:2018, VDE-AR-N 4120:2018, EN 50549, AS/NZS 4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA DRRG, NRS 097-2-1, MEA/PEA, C10/11, G98/G99 |
|||||
Safety / EMC |
IEC 62109-1:2010, IEC 62109-2:2011, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011 | |||||
General Data | ||||||
Dimensions (W x H x D) |
534 x 440 x 220 mm |
|||||
Weight | 24kg | |||||
Operating Temperature Range | -25° C ~ +60° C | |||||
Cooling Method | Smart Cooling | |||||
Protection Degree | IP66 | |||||
Max. Operating Altitude | 4000m | |||||
Relative Humidity |
0 ~ 100% |
|||||
Topology | Transformerless | |||||
Night Power Consumption | <1W | |||||
Warranty | 5 years (Standard) / 10 years (Optional) |