XG 100-136kW INVT Three-Phase On-Grid Solar Inverter XG 100-136kW
1. Efficient
* Support over capacity ratio: 1.6X DC input overload
* High energy continuous output: 1.1X AC output overload
* The MPPT efficiency is up to 99.90%
* The lowest starting voltage can reach to 160V
2. Flexible
* Intelligent IV scanning function: it can accurately locate the fault string and make the operation and maintenance more efficient
* 9~12 MPPT : more flexible string configuration and more choices for installation
* Remote maintenance: support online remote upgrade
* Fan drawer design: 1 minute quick fan replacement
3. Reliable
* IP66
* Anti-islanding protection, Input over current proteciton, Output over current protection, DC reverse connection protection, String fault protection, Surge protection, Insulation resistance detection, AC leakage current detection, PID repair, Low voltage ride through, Arc fault detection, Night SVG function, etc.
4. Intelligent
* Intelligent monitoring: one-stop intelligent operation and maintenance platform for users, providing comprehensive and intuitive power station data monitoring
* Support RS485 / USB / WiFi / GPRS
INVT Inverters
Product Feature
Product Introduction
XG100KTR | XG1OOKTR-F | XG11OKTR | XG11OKTR-F | XG136KTR-L | XG136KTR-LF | XG136KTR-X I | XG136KTR-XF | |
Input (DC) | ||||||||
Max. Input Power | 150kW | 160kW | ||||||
Max. Input Voltage | 1100V | |||||||
Start Voltage | 250V | |||||||
Rated Input Voltage | 620V | 730V | 780V | |||||
Full-load MPP Voltage Range | 530V ~ 850V | 560V ~ 850V | ||||||
MPPT Voltage Range | 180V-1000V | |||||||
Numberof MPP Trackers/String per M PPT | 9/2 | 10/2 | 12/2 | |||||
Max. Current perMPPT | 26A | 30A | 26A | 30A | 26A | 30A | 26A | 30A |
Max. Short Circuit Current | 40A | |||||||
Output (AC) | ||||||||
Max. Output Current | 158.8A | 174.6A | 160.4A | |||||
Rated Output Power | 100kW | 110kW | 136kW | |||||
Max. Output Power | 110kVA | 121kVA | 150kVA | |||||
Rated Grid Frequency | 50Hz/60Hz | |||||||
Rated Grid Voltage | 230Vac / 400Vac, 3L/N/PE, 3L / PE | 277Vac/480Vac,3L/N/PE.3L/PE 311Vac/540Vac,3L/N/PE,3L/PE | ||||||
Power Factor | >0.99 (0.8 leading-0.8 lagging) | |||||||
THDi | <3% (Rated Power) | |||||||
Efficiency | ||||||||
Max. Efficiency | 98.70% | |||||||
European Efficiency | 98.50% | |||||||
MPPT Efficiency | 99.90% | |||||||
Protection | ||||||||
DC reverse polarity protection | Yes | |||||||
Anti-islanding protection | Yes | |||||||
AC short circuit protection | Yes | |||||||
Residual current monitoring unit | Yes | |||||||
Insulation resistance monitoring | Yes | |||||||
Ground fault monitoring | Yes | |||||||
Grid monitoring | Yes | |||||||
PV string monitoring | Yes | |||||||
Surge protection | Type II | |||||||
AFCI protection | Optional | |||||||
PID recovery function | Optional | |||||||
SVG function | Optional | |||||||
Communication | ||||||||
Display | LED / LCD / Bluetooth+App | |||||||
Communication | Standard: RS485/USB Optional: WiFi/DRM/Bluetooth | |||||||
Standard Compliance | ||||||||
Grid Connection Standards | IEC 61727,1 EC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4105:2018, VDE-AR-N 4120:2018, EN 50549, AS/NZS 4777.2:2015, CEl 0-21, VDE 0126-1-1/A1 VFR 2014,UTE C15-712-l:2013, DEWA DRRG, NRS 097-2-1, MEA/PEA, C10/11, G98/G99 | |||||||
Safety/EMC | IEC 62109-1:2010, IEC 62109-2:2011, EN 61000-6-2:2005, EN 61000-6-3:2007/Al:2011 | |||||||
General Data | ||||||||
Dimensions (W x H x D) | 1050 x 660 x 330 mm | |||||||
Weight | 95kg | 98kg | 101kg | |||||
Operating Temperature Range | -30°C'+60°C | |||||||
Cooling Method | Smart Cooling | |||||||
Protection Degree | IP66 | |||||||
Max. Operating Altitude | 4000m | |||||||
Relative Humidity | 0-100% | |||||||
Topology | Transformerless | |||||||
Night Power Consumption | <1W | |||||||
Warranty | 5 years (Standard) /10 years (Optional) |